+86-312-6775656

HZCR1820/1820B Non-Contact High Voltage Electroscope

Feb 22, 2023

HZCR1820/1820B Non-Contact High Voltage Electroscope

Non-Contact High Voltage Electroscope

Product Function

Applied to on-site high voltage line electricity testing, identify voltage level of high voltage system, inspect fault of high voltage line, repair the inspect induced voltage of the neon lamp, high voltage sodium lamp, inspect residual high voltage or induced voltage, etc.

Product Features

1. Adopt non-contact induction technology, no need to contact with charged body, to ensure the safety of operators.

2. Bright red LED and harsh buzzer sound and light alarm, easy to identify.

3. The nine voltage grade gear cover variety of voltage levels. And it can be customized the voltage grade gear according to user demand.

4. Self - inspect function to ensure the accuracy of electricity testing.

5. Protection Level: IP65.

Voltage Grade and Gear of Electricity Testing

Model

Gear

HZCR1820

OFF--TEST--380V--6.6KV--10KV--35KV--66KV--110KV--220KV--330KV--500KV

HZCR1820B

OFF--TEST--240V--3.3KV--6KV--11KV--22KV--33KV--66KV--132KV--275KV

 

 Technical Specifications 

Function

on-site high voltage line electricity testing, identify voltage level of high voltage system, inspect fault of high voltage line, repair the inspect induced voltage of the neon lamp, high voltage sodium lamp, inspect residual high voltage or induced voltage, etc.

Power Supply

Zn-Mn dry battery 6F22, 9V

Voltage Gear

Nine gears

Electricity Test Range

240V~500KV(optinal)

Electricity Test Level

380V,6.6kV,10kV,35kV,66kV,110kV,220kV

Voltage to Earth Display Range

0.1kV~150kV(Voltage to earth)

Electricity Test Indication

Red flashes LED light indication

"beep - beep - beep" buzzing sound.

Self-inspect Function

Turn the knob to "TEST" gear, the indicator light on, and the buzzer will make sound of "beep-".

Low Battery Voltage Indication

When the detector battery voltage is lower than 7.2V±0.1V, the green power indicator flashes; when the receiver voltage lower than 4.8V±0.1V, low battery voltage symbol “      ” will display and remind to replace battery.

Protection Level

IP65

Instrument Weight

Instrument: 520g; Package and insulation rod total weight: 4.6kg

Instrument Dimension

300mm×237mm×85mm

Insulation Rod Length

Max Diameter:Ø38mm; Length: Contraction state 1000mm; Stretched state 4500mm

Insulation Test

The insulated rod both ends after stretched: AC 220KV/rms

Receiver, detector: AC 3700V/rms(between the exposure metal and plastic shell).

Working Temperature And Humidity

-10℃~40℃;below 80%rh

Store Temperature And Humidity

-10℃~60℃;below 70%rh

Accessories

Detector:1PCS; Scalable Insulation Rod: 1PCS; Tool Bag: 1PCS